NB SERIES · C-TYPE COIN SUPERCAPACITOR

NB5R5C474N-E 5.0 V 0.47 F C-Type Coin Supercapacitor

A compact, polarized C-type coin supercapacitor for RTC backup, memory retention and low-current hold-up. It combines a 5.0 V rated operating voltage, 5.5 V surge capability and 0.47 F nominal capacitance in a Ø13.3 × 7.0 mm body.

Product scope: This engineering summary is based on the supplied NB5R5C474N-E specification. The controlled PDF remains the authority for final dimensions, test conditions, qualification and production release.

Verify the latest controlled revision and application conditions before design approval.

NYFEA NB5R5C474N-E 5.0 V rated, 5.5 V surge, 0.47 F C-type coin supercapacitor
Product appearance is shown for identification. Use the controlled drawing for dimensions, polarity and lead configuration.
5.0 VRated operating voltage
0.47 FNominal capacitance
20 ΩMaximum ESR at 1 kHz, 10 mA
Ø13.3 × 7.0 mmBody diameter × thickness

Product Overview and Selection Scope

NB5R5C474N-E is a 5.0 V rated, 5.5 V surge, 0.47 F C-type coin supercapacitor with same-side solder tabs. Its small Ø13.3 mm package is intended for RTC backup, low-power state retention and short data-save intervals where PCB area is limited.

Energy-type coin constructionPolarized NB-series package with same-side C-type solder tabs.
0.47 F nominal capacitanceGeneral tolerance −20% to +80%; controlled option −10% to +20%.
−25 to +70 °C operationSpecified across the standard E-type operating temperature range.
8 µA leakage limitSpecified after 24 hours at the 5.0 V rated operating voltage.
20 Ω maximum ESRSpecified at 1 kHz, 10 mA and room temperature.
Compact through-hole formatØ13.3 × 7.0 mm body with 5.0 mm terminal spacing.
Selection boundary
This device is polarized and its terminal voltage falls during discharge. Verify the ESR step, capacitance tolerance, load profile, leakage, charging current and minimum system voltage in the complete circuit.

Part-Number Construction

The designation is decoded below using the naming table in the supplied specification.

NBCoin-cell series5R55.5 V surge codeCC-type tabs4740.47 FNSource tolerance codeEEnergy type
SegmentMeaningValue for this productEngineering note
NBSeriesCoin supercapacitorIdentifies the source NB button-type product family.
5R5Series voltage code5.5 V surgeThe continuous rated operating voltage is 5.0 V.
CTerminal formatC-type same-side solder tabsConfirm the footprint and marked polarity before PCB release.
474Capacitance code0.47 FNominal capacitance before tolerance, temperature and ageing margins.
NCapacitance tolerance codeSource designationThe product-performance table specifies −20% to +80%; that controlled value governs this page.
EFunction codeEnergy typeSource naming classification; not a system-level power rating.

Electrical Characteristics

Values below are transcribed from the supplied NYFEA specification. Rated operating voltage and surge voltage are separate limits.

ParameterConditionSpecified valueUnit
Rated operating voltageUR5.0V
Surge voltageMaximum source-specified surge5.5V
Nominal capacitanceC0.47F
General capacitance toleranceIEC 62391-1−20 to +80%
Controlled capacitance toleranceControlled option−10 to +20%
Category temperature rangeAmbient−25 to +70°C
Maximum ESR1 kHz, 10 mA, room temperature20Ω
Leakage currentAfter 24 h at rated voltage8µA
Voltage distinction: 5.0 V is the continuous rated operating voltage. The 5.5 V value is the surge limit and must not be presented as the continuous rating.

Mechanical Dimensions and Polarity

The component uses a polarized C-type coin construction with both solder tabs extending from the same side. Confirm PCB polarity before assembly.

NB5R5C474N-E C-type coin supercapacitor mechanical drawing
English engineering redraw based on the supplied dimension drawing. All dimensions are in millimetres.
DimensionNominalToleranceDesign use
Body diameter13.3 mm±0.3 mmCylindrical envelope
Body thickness7.0 mm±0.2 mmAxial package depth
Terminal spacing5.0 mm±0.5 mmPCB hole spacing
Lead projection5.0 mm±1.0 mmMinimum layout allowance
Terminal features0.8 / 1.2 / 0.4 mm±0.2 / ±0.2 / ±0.02 mmVerify the released PCB footprint against the source drawing.

Reliability and Endurance

TestSource conditionCapacitance requirementESR requirement
Load life5.0 V at +70 ±2 °C for 1000 hDecrease ≤30% from initial≤4 × specified value
Temperature characteristics+25 ±2 °C, +70 ±2 °C and −25 ±2 °C source test pointsPer the source limits at each test point≤4 × specified value at temperature extremes
Temperature cyclingFive cycles: −25 °C → room temperature → +70 °C → room temperatureDecrease ≤30% from initial≤3 × specified value
Storage lifeCharged to rated voltage for 1000 h within the source-defined −25 to +70 °C conditionDecrease ≤30% from initial≤4 × initial value
Cycle life500,000 constant-current cycles between rated and half-rated voltage at +25 °CWithin ±30% of initial≤3 × initial value

Capacitance and ESR Test Methods

For capacitance measurement, charge the device to rated voltage for 30 minutes and discharge it at the prescribed constant current. ESR is measured using the specified 1 kHz AC method.

Capacitance discharge test profile
The supplied capacitance method uses a 10 mA constant-current charge/discharge procedure; ESR is measured at 1 kHz and 10 mA.
1 kHz AC ESR measurement circuit
AC ESR test at 1 kHz with the source-specified test-current range of 1–10 mA.
CapacitanceC = I(t₂ − t₁) / (U₁ − U₂)
AC resistanceRAC = U / I

Hold-Up, Leakage and Energy Calculations

Estimate the usable interval from the allowable voltage window and load current, then subtract the immediate ESR voltage step. For leakage-current verification, apply the 5.0 V rated operating voltage and measure the current after the source-specified 24-hour charging period.

Ideal constant-current hold-upt ≈ C(Vstart − Vmin) / Iload
Initial ESR dropΔVESR = Iload × ESR
Maximum stored energyE = 0.5CUR2 / 3600
Calculation note: At nominal C = 0.47 F and the 5.0 V rated operating voltage, ideal stored energy is approximately 0.00163 Wh. Available system energy will be lower because of the minimum operating voltage, ESR, leakage, capacitance tolerance, temperature and ageing.

PCB Mounting, Soldering and Handling

Assembly and environmental conditions directly affect reliability. Apply the following source-specification precautions during layout and process qualification.

Observe polarityReverse connection can damage the device and create a safety risk.
Stay below 5.5 VOvervoltage can drive electrolyte decomposition, heating, capacitance loss and ESR increase.
Avoid rapid high-frequency cyclingUse a validated current and thermal profile for repetitive charge–discharge operation.
Protect the body and leadsDo not tilt, twist or force the package after soldering; keep the body clear of the PCB surface.
Control solderingFor a 1.6 mm PCB, the source limit is 260 °C maximum for no more than 5 seconds.
Control storageStore from −30 to +50 °C at less than 60% RH, away from corrosive or toxic gases and rapid temperature changes.
Series connection
If devices are connected in series, implement voltage balancing and obtain NYFEA application guidance. Also validate hole size, lead pitch, cleaning chemistry, polarity inspection and mechanical support before release.

Application Guidance and Design Limitations

The applications below are engineering use cases consistent with a compact 5.0 V rated, 0.47 F backup component. They are not end-product certification claims.

RTC backupRTC BackupMaintain timekeeping through a brief loss of the main supply.
Memory retentionMemory RetentionSupport low-power state preservation and orderly data save.
Smart meter data saveSmart Meter Data SaveProvide a short window for nonvolatile recording after mains loss.
Compact control nodeCompact Control NodesBridge short interruptions after validating the load and voltage window.
Wireless sensor backupWireless Sensor BackupMaintain low-power state between supply events after circuit validation.
Qualification boundary
The source specification does not claim automotive, medical, functional-safety, life-support or fault-tolerant qualification. Confirm all mandatory standards for the end product.

NB5R5C474N-E Engineering FAQs

What are the rated voltage and nominal capacitance?

The rated operating voltage is 5.0 V, the surge voltage is 5.5 V, and the nominal capacitance is 0.47 F.

What capacitance tolerance is specified?

The supplied specification states −20% to +80%, corresponding to an initial range of 0.8 F to 1.8 F before additional temperature and ageing allowances.

What is the maximum ESR?

The maximum ESR is 20 Ω at 1 kHz and 10 mA at room temperature.

What is the operating temperature range?

The specified operating range is −25 °C to +70 °C.

What are the package dimensions and lead pitch?

The body is Ø13.3 ±0.3 × 7.0 ±0.2 mm, with 5.0 ±0.5 mm terminal spacing and flat C-type tabs.

Is the component polarized?

Yes. Match the negative marking to the PCB polarity before soldering.

Can it be used as a direct battery replacement?

No. A supercapacitor has continuous voltage decay and an ESR-related voltage step. Validate the load current, minimum system voltage, usable energy and required hold-up time.

What is the difference between rated and surge voltage?

Use 5.0 V as the continuous rated operating voltage. The 5.5 V value is the source-specified surge voltage, not the continuous rating.

Which document controls production decisions?

The supplied NB5R5C474N-E PDF and the current NYFEA-controlled revision remain the design authority.

Technical source and design authority

This page summarizes the supplied NB5R5C474N-E product specification for component evaluation. Confirm the current revision, dimensions, polarity, rated-versus-surge voltage, test conditions, assembly process and qualification requirements before production release.

© 2023 All Rights Reserved. www.nyfea.com Terms of Use | Privacy Policy