NB SERIES · H-TYPE COIN SUPERCAPACITOR

NB5R5H505N-E 5.0 V 5.0 F H-Type Coin Supercapacitor

A polarized H-type coin supercapacitor combining a 5.0 V continuous rating, 5.5 V surge limit and 5.0 F nominal capacitance in an approximately Ø24.7 × 6.0 mm body.

Product scope: This engineering summary is based on the supplied NB5R5H505N-E specification. The controlled PDF remains the authority for production release.

Verify the latest controlled revision and application conditions before design approval.

NYFEA NB5R5H505N-E 5.0 V 5.0 F H-type coin supercapacitor
Product appearance is shown for identification. Use the controlled drawing for dimensions, polarity and lead configuration.
5.0 VRated operating voltage
5.0 FNominal capacitance
10 ΩMaximum ESR at 1 kHz, 10 mA
Ø24.7 × 6.0 mmMain body diameter × thickness

Product Overview and Selection Scope

NB5R5H505N-E is a 5.0 V rated, 5.5 V surge, 5.0 F H-type coin supercapacitor with polarized solder tabs arranged on opposite axial faces.

H-type coin constructionPolarized tabs on opposite axial faces for PCB mounting.
5.0 F nominal capacitanceProduct-specific tolerance −20% to +80%; controlled option −10% to +20%.
−25 to +70 °C operationSpecified across a broad operating temperature range.
15 µA leakage limitSpecified after 24 hours at the 5.0 V rated operating voltage.
Low leakage limit0.002 mA maximum after 72 hours at rated voltage.
H-type formatApproximately Ø24.7 × 6.0 mm body with opposite-face polarized solder tabs.
Selection boundary
This device is polarized and its terminal voltage falls during discharge. Verify the ESR step, capacitance tolerance, load profile, leakage, charging current and minimum system voltage in the complete circuit.

Part-Number Construction

The designation is decoded below using the naming table in the supplied specification.

NBCoin-cell series5R55.5 V surgeHH-type tabs5055.0 FNTolerance codeEEnergy type
SegmentMeaningValue for this productEngineering note
NBSeriesCoin-type supercapacitorIdentifies the coin-cell product family.
5R5Series voltage code5.0 V rated / 5.5 V surgeUse 5.0 V for continuous operation; 5.5 V is the surge limit.
HTerminal formatH-type polarized tabsConfirm the opposite-face terminal geometry and polarity before PCB release.
505Capacitance code5.0 FNominal capacitance before tolerance and ageing margins.
NTolerance codeProduct specification: −20% to +80%Use 4.0 F as the initial minimum for conservative calculations.
EVariant codeStandard product variantConfirm the exact ordering code on the controlled specification.

Electrical Characteristics

Values below are transcribed from the supplied NYFEA specification. Rated operating voltage and surge voltage are separate limits.

ParameterConditionSpecified valueUnit
Rated operating voltageUR5.0V
Surge voltageMaximum source-specified surge5.5V
Nominal capacitanceC5.0F
General capacitance toleranceIEC 62391-1−20 to +80%
Controlled capacitance toleranceControlled option−10 to +20%
Category temperature rangeAmbient−25 to +70°C
Maximum ESR1 kHz, 10 mA, room temperature10Ω
Leakage currentAfter 24 h at rated voltage15µA
Voltage distinction: 5.0 V is the continuous rated operating voltage. The 5.5 V value is the surge limit and must not be presented as the continuous rating.

Mechanical Dimensions and Polarity

The component uses a polarized H-type coin construction. The solder tabs are attached on opposite axial faces, as shown in the controlled mechanical drawing. Confirm PCB polarity and the full terminal envelope before assembly.

NB5R5H505N-E H-type coin supercapacitor mechanical drawing
English engineering redraw based on the supplied dimension drawing. All dimensions are in millimetres.
DimensionNominalToleranceDesign use
Body diameter24.7 mm+0.3 / −0.1 mmMain cylindrical envelope
Body thickness6.0 mm±0.3 mmAxial package depth
Terminal-envelope reference9.7 mm+0.3 mmUse the controlled drawing datum for final PCB clearance
Tab width3.5 mm±0.2 mmTerminal width shown in the side view
Slot width1.8 mm±0.2 mmElongated terminal opening
Tab thickness0.2 mm±0.02 mmTerminal cross-section

Reliability and Endurance

TestSource conditionCapacitance requirementESR requirement
Load life5.0 V at +70 ±2 °C for 1000 hDecrease ≤30% from initial≤4 × specified value
Temperature cyclingFive cycles: −25 °C → room temperature → +70 °C → room temperatureDecrease ≤30% from initial≤3 × specified value
Storage lifeSource-defined 1000 h condition within −25 to +70 °CDecrease ≤30% from initial≤4 × initial
Cycle life500,000 constant-current cycles between specified and half-specified voltage at +25 °CWithin ±30% of initial≤3 × initial

Capacitance and ESR Test Methods

For capacitance measurement, charge the device to rated voltage for 30 minutes and discharge it at the prescribed constant current. ESR is measured using the specified 1 kHz AC method.

Capacitance discharge test profile
The supplied method uses a 10 mA constant-current discharge after a 30-minute constant-voltage charge.
1 kHz AC ESR measurement circuit
AC ESR test at 1 kHz with the source-specified test-current range of 1–10 mA.
CapacitanceC = I(t₂ − t₁) / (U₁ − U₂)
AC resistanceRAC = U / I

Hold-Up, Leakage and Energy Calculations

Estimate the usable interval from the allowable voltage window and load current, then subtract the immediate ESR voltage step. For leakage-current testing, fully discharge the device for at least one hour, apply rated voltage, and evaluate the source-specified 24-hour leakage limit.

Ideal constant-current hold-upt ≈ C(Vstart − Vmin) / Iload
Initial ESR dropΔVESR = Iload × ESR
Maximum stored energyE = 0.5CUR2 / 3600
Calculation note: At nominal C = 5.0 F and 5.0 V, ideal stored energy is approximately 0.0174 Wh. Available system energy will be lower in service.

PCB Mounting, Soldering and Handling

Assembly and environmental conditions directly affect reliability. Apply the following source-specification precautions during layout and process qualification.

Observe polarityReverse connection can damage the device and create a safety risk.
Stay below 5.5 VOvervoltage can drive electrolyte decomposition, heating, capacitance loss and ESR increase.
Avoid rapid high-frequency cyclingUse a validated current and thermal profile for repetitive charge–discharge operation.
Protect the body and leadsDo not tilt, twist or force the package after soldering; keep the body clear of the PCB surface.
Control solderingFor a 1.6 mm PCB, the source limit is 260 °C maximum for no more than 5 seconds.
Control storageStore from −30 to +50 °C at less than 60% RH, away from corrosive or toxic gases and rapid temperature changes.
Series connection
If devices are connected in series, implement voltage balancing and obtain NYFEA application guidance. Also validate hole size, lead pitch, cleaning chemistry, polarity inspection and mechanical support before release.

Application Guidance and Design Limitations

The applications below are engineering use cases consistent with a 5.0 V rated, 5.0 F backup component. They are not end-product certification claims.

RTC backupRTC BackupMaintain timekeeping through a brief loss of the main supply.
Memory retentionMemory RetentionSupport low-power state preservation and orderly data save.
Smart meter data saveSmart Meter Data SaveProvide a short window for nonvolatile recording after mains loss.
Compact control nodeCompact Control NodesBridge short interruptions after validating the source-listed current limit.
Wireless sensor backupWireless Sensor BackupMaintain low-power state between supply events after circuit validation.
Qualification boundary
The source specification does not claim automotive, medical, functional-safety, life-support or fault-tolerant qualification. Confirm all mandatory standards for the end product.

NB5R5H505N-E Engineering FAQs

What are the rated voltage and nominal capacitance?

The rated operating voltage is 5.0 V, the surge voltage is 5.5 V, and the nominal capacitance is 5.0 F.

What capacitance tolerance is specified?

The product specification states −20% to +80%, corresponding to an initial range of 4.0 F to 9.0 F.

What is the maximum ESR?

The maximum ESR is 10 Ω at 1 kHz and 10 mA at room temperature.

What is the operating temperature range?

The specified operating range is −25 °C to +70 °C.

What are the package dimensions and terminal arrangement?

The source drawing specifies an approximately Ø24.7 mm body with 6.0 ±0.3 mm thickness. The H-type solder tabs are attached on opposite axial faces; use the controlled drawing for the complete footprint.

Is the component polarized?

Yes. Match the negative marking to the PCB polarity before soldering.

Can it be used as a direct battery replacement?

No. A supercapacitor has continuous voltage decay and an ESR-related voltage step. Validate the load current, minimum system voltage, usable energy and required hold-up time.

What is the difference between rated and surge voltage?

Use 5.0 V as the continuous rated operating voltage. The 5.5 V value is the source-specified surge voltage, not the continuous rating.

Which document controls production decisions?

The supplied NB5R5H505N-E PDF and the current NYFEA-controlled revision remain the design authority.

Technical source and design authority

This page summarizes the supplied NB5R5H505N-E product specification for component evaluation.

© 2023 All Rights Reserved. www.nyfea.com Terms of Use | Privacy Policy