Choosing a Digital Humidity and Temperature Sensor: NYFEA FHT41
Consider NYFEA FHT41 if your custom PCB needs relative humidity and temperature measurements over I²C in a 1.50 × 1.50 mm DFN-4 package. Its 1.6–5.5 V supply range includes 3.3 V. NYFEA specifies typical accuracy of ±1.8% RH and ±0.2 °C under specified conditions. Compare the accuracy curves with your operating range, then check bus compatibility and verify readings in the finished enclosure. View the FHT41 product specifications.

When should you choose the NYFEA FHT41 for a custom PCB?
Shortlist the FHT41 for a compact indoor monitor when you have an I²C controller, room for a vented sensing location, and an accuracy target you can check against the datasheet. Use the table to decide whether to proceed to samples.
| Design requirement | FHT41 feature | Selection check |
|---|---|---|
| Limited PCB space | 1.5 × 1.5 mm DFN-4 | Allow space for the footprint, supporting components and an effective air path. |
| Both environmental measurements | Relative humidity and temperature | Compare accuracy curves with your full operating range. |
| Microcontroller integration | I²C digital interface | Confirm bus voltage, exact order-code address and driver timing. |
| Power-budget constraints | Three repeatability modes | Choose a mode using measured consistency and complete-system consumption. |
| Existing power rail | 1.6–5.5 V supply | Check supply tolerance and interface levels separately. |

What is inside the FHT41?
The FHT41 functional diagram shows the relative humidity and temperature sensing elements feeding an analog-to-digital converter (ADC). Data processing uses calibration memory. The I²C interface connects the device to the host.

What accuracy does FHT41 provide?
NYFEA specifies typical FHT41 accuracy of ±1.8% RH and ±0.2 °C under specified conditions. The sensor measures 0–100% RH and −40 to +125 °C. Those ranges describe what the sensor measures. Use the maximum-error curves to assess accuracy at the conditions your product will encounter. FHT41 datasheet, Figures 2–4.
For example, at 25 °C and 50% RH, Figure 2 shows a maximum humidity error of about ±2.5 percentage points. If the finished monitor requires ±2% RH at that point, the typical ±1.8% RH figure alone cannot support approval. Budget for the sensor limits, assembly effects and reference uncertainty before defining your acceptance test.
Define the maximum error your finished device can accept. Include reference uncertainty and installation effects in the error budget. Accuracy measures agreement with a reference; repeatability describes variation under unchanged conditions; resolution describes the smallest reported increment. A finer resolution or higher repeatability does not eliminate systematic error.
Which measurement mode should you choose?
Start with low repeatability for a battery-powered monitor and compare it with the other modes if reading variation affects a display or alarm. At one measurement per second, NYFEA lists typical average sensor currents of 0.4 µA in low, 1.2 µA in medium and 2 µA in high repeatability. Typical electrical conditions are 25 °C and 3.3 V. FHT41 electrical characteristics.
Compare modes in a stable environment and check whether reading variation matters to your display, alarm or control algorithm. Select the lowest-energy mode that satisfies the requirement. Include the controller, radio, regulator losses and heater operation in the product budget. The fivefold ratio between the listed high- and low-repeatability currents does not establish a fivefold battery-life improvement.
How do you connect FHT41 to a microcontroller?
Connect FHT41 pin 1 (SDA) and pin 2 (SCL) to the controller’s I²C bus, pin 3 (VDD) to the sensor supply, and pin 4 (VSS) to ground. The NYFEA reference circuit shows two 10 kΩ pull-ups and a 100 nF decoupling capacitor. FHT41 datasheet, Figure 6.

Use the figure as a starting point. Select the pull-ups for the bus capacitance, speed and rise-time requirement, and place the bypass capacitor close to the sensor supply pins. Confirm the bus address for the supplied order code before setting up firmware.
Design example: a compact 3.3 V room monitor
In this design example, a compact room monitor uses a 3.3 V supply and an I²C microcontroller. The supply is within the FHT41’s 1.6–5.5 V range. Begin with the bus and footprint, then compare the assembled monitor with a reference under representative power and airflow conditions.

- Set the measurement requirement. Record the operating range, allowable error and reporting interval. Compare them with the accuracy curves.
- Check electrical integration. Confirm the exact supplied order code, I²C address, logic levels, pull-ups, decoupling and conversion timing against current documentation.
- Plan the air path. Place the sensing opening where it samples room air, away from processors, displays and regulators. Review ventilation and PCB heat conduction.
- Evaluate the assembled monitor. Compare it with a suitable reference across the required conditions, using representative power states and the final enclosure.
Record PCB revision, firmware, reference uncertainty, settling time and acceptance limits. A shift when electronics become active suggests investigating thermal coupling. A slower response after fitting the enclosure suggests investigating airflow. NYFEA installation guidance.
Common selection questions
Can FHT41 run on 3.3 V?
Yes. A 3.3 V supply falls within the FHT41’s 1.6–5.5 V range. Confirm that the host and sensor meet the I²C logic levels, and size the pull-ups for your bus.
Can FHT41 be considered for a battery-powered monitor?
Yes. Its selectable modes make it a candidate for evaluation. Choose mode and sampling interval using the complete product’s energy budget and measurement requirements.
Does the integrated heater make FHT41 waterproof?
An integrated heater does not establish a waterproof rating. Normal accuracy specifications do not apply during heating; allow thermal recovery before interpreting readings as ambient measurements.
What information should I provide with a sample request?
Provide supply voltage, controller interface, operating range, accuracy target, sampling interval, enclosure conditions and expected quantity. Include the schematic and footprint for an existing board.
Request FHT41 samples and design support
Share your requirements to discuss sample availability, pricing and integration. View FHT41 specifications or request samples or a quote. For wider selection, explore the NYFEA temperature and humidity sensor range.
Technical sources
- NYFEA FHT41 datasheet (PDF). Pages 2, 4–8 and 12–14 cover the functional blocks, pin functions, accuracy curves, wiring, package and recommended PCB land pattern.
- NYFEA FHT41 product documentation — specifications, accuracy curves and electrical characteristics.
- NYFEA sensor selection and installation guidance.
FHT41 and NYFEA identify the NYFEA product and brand. This guide provides component-selection guidance and does not report independent hardware validation.






